{"id":5048,"date":"2024-02-20T08:04:09","date_gmt":"2024-02-20T08:04:09","guid":{"rendered":"https:\/\/dev.mechanc.com\/?post_type=product&#038;p=5048"},"modified":"2026-09-10T13:30:18","modified_gmt":"2026-09-10T13:30:18","slug":"2-92mm-female-2-hole-flange-rf-connector-0-3mm-pin-diameter-2-92-kfd17","status":"publish","type":"product","link":"https:\/\/dev.mechanc.com\/de\/produkt\/2-92mm-female-2-hole-flange-rf-connector-0-3mm-pin-diameter-2-92-kfd17\/","title":{"rendered":"HF-Steckverbinder 2,92 mm, Buchse, 2-Loch-Flanschmontage \u2013 vor Ort austauschbar, Lochabstand 12,22 mm, Stiftdurchmesser 0,3 mm"},"content":{"rendered":"<h2>2,92-mm-HF-Steckverbinder (Buchse) mit 2-Loch-Flanschmontage, feldaustauschbar \u2013 Modell 2.92-KFD17<\/h2>\n<p>Der <strong>2,92-mm-HF-Steckverbinder (Buchse) mit 2-Loch-Flanschmontage<\/strong> mit 0,30 mm Stift und 12,22 mm Lochabstand liefert eine ausgezeichnete Signaltreue und eine mechanische Festigkeit f\u00fcr breitbandige HF-Anwendungen bis 40 GHz. Dieser <a href=\"https:\/\/www.mechanc.com\/rf-connectors\/field-replaceable-connectors\/\">feldaustauschbarer Steckverbinder<\/a> bietet eine verl\u00e4ssliche elektrische Stabilit\u00e4t in wiederholten Pr\u00fcfzyklen.<\/p>\n<h3>Elektrische Leistung<\/h3>\n<p>Der <strong>2,92-mm-HF-Steckverbinder (Buchse) mit 2-Loch-Flanschmontage<\/strong> erreicht VSWR \u2264 1,15 und eine Einf\u00fcged\u00e4mpfung \u2264 0,06 \u221aF(GHz) dB und sichert damit eine verlustarme \u00dcbertragung und eine Phasengenauigkeit. Die 0,30-mm-Stiftauslegung w\u00e4gt die Robustheit des Kontakts gegen eine feine Ausrichtung ab.<\/p>\n<h3>Werkstoffe und Konformit\u00e4t<\/h3>\n<p>Aus Edelstahl und goldbeschichtetem Berylliumkupfer gefertigt, bietet der <strong>2,92-mm-Flanschsteckverbinder (Buchse)<\/strong> eine herausragende Haltbarkeit und erf\u00fcllt vollst\u00e4ndig die <strong>REACH- und RoHS-Normen<\/strong>.<\/p>\n<h3>Anwendungen<\/h3>\n<p>Eingesetzt in modularen Analysatoren, Signalverteilfeldern und <a href=\"https:\/\/www.mechanc.com\/rf-connectors\/2-hole-flange-mount\/\">HF-Baugruppen mit 2-Loch-Flanschmontage<\/a>, bei denen eine optimale Raumnutzung und eine mechanische Pr\u00e4zision unerl\u00e4sslich sind.<\/p>\n<h3>Steckerausf\u00fchrung<\/h3>\n<p>Kombinieren Sie ihn mit dem <a href=\"https:\/\/www.mechanc.com\/rf-connectors\/2-92mm-male-2-hole-flange-rf-connector-0-3mm-pin-diameter-2-92-jfd17\/\">2,92-mm-HF-Steckverbinder (Stecker) mit 2-Loch-Flanschmontage \u2013 Modell 2.92-JFD17<\/a>. Die vollst\u00e4ndige <a href=\"https:\/\/www.mechanc.com\/rf-connectors\/2-92mm-connectors\/\">2,92-mm-HF-Steckverbinderserie<\/a> finden Sie in unserem <a href=\"https:\/\/dev.mechanc.com\/product-category\/rf-connectors\/\">HF-Steckverbinder-Katalog<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>2,92-mm-HF-Steckverbinder (Buchse) mit 2-Loch-Flanschmontage, feldaustauschbar \u2013 Modell 2.92-KFD17 Der 2,92-mm-HF-Steckverbinder (Buchse) mit 2-Loch-Flanschmontage mit 0,30 mm Stift und 12,22 mm Lochabstand liefert eine ausgezeichnete Signaltreue und eine mechanische Festigkeit f\u00fcr breitbandige HF-Anwendungen bis 40 GHz. Dieser feldaustauschbarer Steckverbinder bietet eine verl\u00e4ssliche elektrische Stabilit\u00e4t in wiederholten Pr\u00fcfzyklen. Elektrische Leistung Der 2,92-mm-HF-Steckverbinder (Buchse) mit 2-Loch-Flanschmontage erreicht VSWR [&hellip;]<\/p>\n","protected":false},"featured_media":1315,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"attachment-method":[162],"body-material":[],"body-style":[151],"center-conductor-type":[],"connection-type":[],"dielectric-type":[],"frequency-max":[191],"connector-gender":[163],"impedance":[152],"interface-type":[],"jacket-material":[],"main-feature":[],"max-operating-temperature":[161],"mount-method":[169],"no-of-shields":[],"connector-series":[195],"termination-type":[166],"vswr-max":[],"vswr-typical":[],"product_brand":[],"product_cat":[47,17],"product_tag":[],"product_application":[],"class_list":["post-5048","product","type-product","status-publish","has-post-thumbnail","attachment-method-field-replaceable","body-style-straight","frequency-max-40-ghz","connector-gender-female","impedance-50-cf89","max-operating-temperature-165c","mount-method-2-hole-flange","connector-series-2-92mm","termination-type-field-replaceable","product_cat-2-92mm-connectors","product_cat-rf-connectors","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/product\/5048","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/comments?post=5048"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/media\/1315"}],"wp:attachment":[{"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/media?parent=5048"}],"wp:term":[{"taxonomy":"attachment-method","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/attachment-method?post=5048"},{"taxonomy":"body-material","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/body-material?post=5048"},{"taxonomy":"body-style","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/body-style?post=5048"},{"taxonomy":"center-conductor-type","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/center-conductor-type?post=5048"},{"taxonomy":"connection-type","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/connection-type?post=5048"},{"taxonomy":"dielectric-type","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/dielectric-type?post=5048"},{"taxonomy":"frequency-max","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/frequency-max?post=5048"},{"taxonomy":"connector-gender","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/connector-gender?post=5048"},{"taxonomy":"impedance","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/impedance?post=5048"},{"taxonomy":"interface-type","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/interface-type?post=5048"},{"taxonomy":"jacket-material","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/jacket-material?post=5048"},{"taxonomy":"main-feature","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/main-feature?post=5048"},{"taxonomy":"max-operating-temperature","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/max-operating-temperature?post=5048"},{"taxonomy":"mount-method","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/mount-method?post=5048"},{"taxonomy":"no-of-shields","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/no-of-shields?post=5048"},{"taxonomy":"connector-series","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/connector-series?post=5048"},{"taxonomy":"termination-type","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/termination-type?post=5048"},{"taxonomy":"vswr-max","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/vswr-max?post=5048"},{"taxonomy":"vswr-typical","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/vswr-typical?post=5048"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/product_brand?post=5048"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/product_cat?post=5048"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/product_tag?post=5048"},{"taxonomy":"product_application","embeddable":true,"href":"https:\/\/dev.mechanc.com\/de\/wp-json\/wp\/v2\/product_application?post=5048"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}